Logo TEMCO Engineering, Inc. Made in the USA

Consistency Experts for the Pulp & Paper industry since 1985!

 

 


Technical Specifications

MAGIC II  SMART + HART 
2-Wire, All Electronic Loop Powered Consistency Transmitter

·        Sensitivity  @ 2.5 % consistency as ± 0.003%
                
@ 4.0 % consistency as
±
0.002 %

·        Power Requirements -  2-wire, 24-30 volts DC, minimum 250 ohm loop resistance.

·        Output Signal - Liner 4-20 ma into 350 ohm max. load @ 24 volts,1300 ohms @ 30 volts.

·        Output Dampening - Silicon oil dampener plus digital electronic filtering, 1.5 to 100 seconds(1.5 sec. factory setting)

·        Output Test Points = 4 ma and 20 ma.

·        Pulp Curves - Ten-calibration curve, 0.5 to 7.0% installed in transmitter. Curve selection via HART communication.

·        Consistency Range - Made in consistency units from any HART Protocol Adjustments device such as a Rosemount 275/375.

·        Consistency Sensing - Standard Motor Driven DeZURIKâ Disc and Shaft to Generate Torque from Consistency changes.

·        Torque Sensing - Non-Contact Inductive coupling with Stationery Pick-Up Coil; approximately .030 in Air Gap.

·        MAGIC II - Can replace any existing pneumatic or electronic DeZurik â transmitter.

·        Sensor Motor Standard 440 vac 3 phase 1/2 hp @ 1 amp. Optional 575 vac motors are available.


 

Temco Engineering

© TEMCO Engineering, Inc. 2004 - All rights reserved.