MAGIC III DHX

TECO is proud to introduce the Magic III DHX . Engineered to operate in a pulp mill. Plus all the features of a Magic III.


  • Double Heat Exchanger - air or water cooled chamber.
  • Cooling water cannot blow out seals and damage the meter.
  • Optional compressed air cooling to conserve water.
  • Designed for an operating environment of 190° black liquor.
  • Consistency measurement “OUTSIDE” the pipe.
  • Nothing to break inside the pipe.
  • Ideal for high “Kappa”, Blow Line applications.

Double Heat Exchanger Cooling – the heat transfer liquid in the first heat exchanger cools and lubricates the process seal. The air or water in the second heat exchanger cools the heat transfer liquid. The air or water is completely isolated, so it Can Not damage any components of the consistency meter.


Double Heat Exchanger Cooling – the heat transfer liquid in the first heat exchanger cools and lubricates the process seal. The air or water in the second heat exchanger cools the heat transfer liquid. The air or water is completely isolated, so it Can Not damage any components of the consistency meter.

Technical Specifications

MAGIC III DHX SMART + HART

  • Power Requirements: 2-wire, 24-29 volts DC, minimum 250 ohm loop resistance. Motor 3 phase 440-480 VAC @ 60 Hz. Optional 110VAC Single Phase @60Hz available
  • Output Signal: 4-20 mA (limited to 23 mA) into 350 ohm max. load @ 24 volts,700 ohms @ 29 volts.
  • Output Dampening: Digital 1.5 to 100 seconds( 5 sec. factory setting )
  • Output Jacks: 4 to 20 ma. Equal Upper & Lower Range
  • Pulp Curves: TEN Calibration curve, 1 to 7% installed in transmitter. Curves selection via HART. Span (Min. 1% Max. 5% )
  • Sensitivity: Better than +/- 0.025% as % consistency
  • Repeatability: +/- 0.3 % full scale (constant operating conditions)
  • Operating Conditions: Max. stock Temp. 275 °F - Ambient Temp.140°F. Max. Process Pressure @ 257°F
  • Materials: Wetted Parts : 316 S/S - Housing : Aluminum
  • Seal Cooling: Double heat exchanger using water in second chamber to cool heat transfer fluid.
  • Consistency Range adjustments made in % consistency from any HART Protocol Adjustment device such as a Meriam™, Rosemount™ or SMAR™ Communicator.
  • Consistency Sensing: Standard Motor Driven Disc and Shaft to Generate Torque from Consistency changes.
  • Torque Sensing: Non-Contact Inductive coupling with Stationery Pick-Up Coil; approximately .030 in Air Gap.
  • MAGIC III  Upgrade: Can be installed on any existing pneumatic or electronic BTG® transmitter.
  • Sensor Motor Standard 440 vac 3 phase 1/2 hp @ 1 amp. Optional 575 vac motors are available.

Why SMART + HART? Contact TECO